TPLS Interiors Ltd installs insulated dry lining across London on refurbishments where external insulation is not an option. Upgrading a solid wall from the inside works well, but it moves the cold side of the wall, and that has to be designed for. Director-led, London-based, trading since 2006.
TL;DR
Insulated dry lining adds insulation to the inside face of an external wall, either as insulated plasterboard laminate bonded or fixed to the wall, or as a framed lining with insulation between the studs and board over. It improves thermal performance without touching the facade, which matters on London buildings where the outside cannot change. The trade-offs are lost floor area, relocated services and condensation risk, which needs a vapour control strategy and a condensation risk assessment. Call 0204 572 0878.
Key Takeaways
- Two main methods: insulated laminate board, or a framed lining with insulation and board
- Insulating internally makes the original wall colder, so condensation risk has to be assessed
- A vapour control layer, correctly lapped and sealed, is usually part of the build-up
- Expect to lose some floor area and to relocate sockets, radiators and window reveals
- Renovating a thermal element can trigger Part L requirements, so check before scoping.
Contents
A lot of London commercial and larger residential stock has solid walls and facades that cannot be altered, whether for planning, conservation or simple cost reasons. Internal insulation is often the only practical way to improve them, and it is a good one when the detail is right.
The Two Main Methods
| Insulated laminate board | Framed lining with insulation | |
|---|---|---|
| Build-up | Plasterboard factory-bonded to insulation, fixed to the wall | Metal or timber frame, insulation between, board over |
| Wall condition needed | Reasonably flat and sound | Copes with uneven walls |
| Service void | Minimal | Yes, behind the board |
| Thickness | Thinner for a given insulation level | Thicker overall |
| Speed | Faster | Slower, more components |
Which is right depends mostly on the wall. A flat, sound wall suits laminate board. An uneven or out-of-plumb wall, or one where services need to run in the lining, usually suits a framed system.
Condensation: The Part That Has to Be Designed
When you insulate the inside of a wall, the original masonry stays colder than it did before. Warm, moist internal air that reaches that cold surface can condense, inside the build-up where nobody sees it until there is damp or mould.
The usual defences are a vapour control layer on the warm side of the insulation, sealed at laps, edges and around penetrations, and a build-up chosen with the wall’s own moisture behaviour in mind. Some traditional solid walls need a more breathable approach rather than a sealed one.
This is why internal insulation should be backed by a condensation risk assessment. In the UK the code of practice for managing moisture in buildings is BS 5250, and manufacturers of insulated lining systems publish guidance for their build-ups. We work to the specified build-up and flag any detail that would compromise the vapour control, especially around windows, floors and ceilings where the layer is most often broken.
Floor Area, Services and Reveals
Three practical consequences to price for:
- Floor area. Every external wall comes inwards by the thickness of the lining. On a large floor plate that adds up, and it matters for lettable area.
- Services. Sockets, switches, radiators and pipework on external walls need relocating or extending. Recessed back boxes break the vapour control layer unless detailed properly.
- Window and door reveals. Reveals are a cold bridge if left uninsulated, but there is often little depth to insulate them. Thin high-performance reveal linings are usually the answer.
Building Regulations and Scope
Approved Document L sets out when work to an existing building’s thermal elements triggers a requirement to improve them. On a refurbishment where walls are being substantially renovated, it is worth confirming early whether that applies, because it changes what the lining has to achieve.
Where the same walls also need acoustic or fire performance, the build-up has to satisfy all of them together. Our guide to insulation in drylining projects covers the acoustic and fire side of insulation in partitions.
Solid walls on a refurbishment?
Send us the drawings and the target performance and we will advise on the build-up and price it.
Working with TPLS Interiors
TPLS Interiors has been delivering dry lining, partitions and suspended ceilings across London since 2006. Founded by Tomasz Platek and Lukasz Swider, whose initials give the company its name, it remains director-led on every project.
We work as a subcontractor to main contractors and directly with project managers, architects and commercial occupiers, on commercial and larger residential projects.
Our material partners include British Gypsum, Knauf, Siniat, Zentia, Ecophon, Rockfon and OWA.
Frequently Asked Questions
Q: What is insulated dry lining?
Insulation added to the inside face of a wall, either as plasterboard factory-bonded to insulation and fixed to the wall, or as a framed lining with insulation between the studs and plasterboard over.
Q: Does internal wall insulation cause condensation?
It can if not designed properly, because the original wall becomes colder. A vapour control layer on the warm side, correctly sealed, and a condensation risk assessment are the usual safeguards. BS 5250 is the UK code of practice for managing moisture in buildings.
Q: Which is better, insulated board or a framed lining?
Insulated laminate board is thinner and faster on flat, sound walls. A framed lining copes with uneven walls and gives a service void, but is thicker.
Q: How much floor area does internal insulation lose?
The thickness of the full lining build-up on every insulated wall. It varies with the insulation used and the method, so it should be checked against the target performance before committing.
Q: Does Part L apply to internal insulation on a refurbishment?
Approved Document L sets out when renovating a thermal element triggers a requirement to improve it. Confirm early on the project whether it applies, because it affects the specification.
Q: Do sockets and radiators need moving?
Usually. Anything on an external wall needs relocating or extending, and recessed back boxes need detailing so they do not break the vapour control layer.
Need an insulated lining package priced?
Get a quote for your London refurbishment.
Or call 0204 572 0878
Lukasz Swider
Lukasz co-founded TPLS Interiors in 2006 alongside Tomasz Platek. He oversees every project personally and has delivered dry lining, partitions and ceilings across more than 500 commercial sites in London for main contractors, developers and corporate occupiers.
✓ RAMS provided
✓ CSCS-qualified teams
✓ Director-led
Share This Article
